Heat Pump Radiators: Will the Ones You Have Be Big Enough?
Last updated:
- Existing radiators can stay if each one still heats its room
- Heat pumps run most efficiently when they send cooler water round
- A room-by-room heat loss calculation sets the size of every radiator
- New or fully replaced wet systems in England should work at 55°C or less
- An MCS installer must give you each radiator's type and size in writing
- The grant comes off the whole quote, not radiators one by one
Planning a heat pump and wondering about your radiators?
Check If You Qualify- Gas Safe registered engineers
- Company No. 16100301

55°C
Max flow temperature, new wet systems
Approved Document L
45°C
Design flow temperature, heat pump home
Approved Document L, 2021
21°C
Living room design temperature
MIS 3005-D
£7,500
Air source heat pump grant
GOV.UK
Can your existing radiators work as heat pump radiators?
Yes, as long as each radiator can still heat its room with the cooler water a heat pump sends. The test is whether a radiator's output, at the planned water temperature, matches the heat its room loses on a cold day, and that takes figures rather than a guess.
The government's own building guidance shows radiators and heat pumps working together. Appendix D of Approved Document L, Volume 1 (2021 edition) gives a good practice specification for a home built with a heat pump, and its heating system line reads "Air source heat pump and radiators", with a design flow temperature of 45°C.
In an existing home that test is run room by room, so the answer can differ from one radiator to the next. Only the ones that fall short need to change.
Why does a heat pump send cooler water to your radiators?
Because both the building rules and the installer standard tie a heat pump's efficiency to the temperature of the water it sends out. That temperature is the flow temperature, and the design of the whole system works backwards from it.
Approved Document L puts this into the heat pump guidance in England. It says the heat pump should be chosen to meet the full space heating requirement at the design condition, accounting "for the space heating flow temperature assumed in the heat emitter circuit(s)", and without counting on extra electric heaters. The 2026 edition, which takes effect on 24 March 2027, adds that the flow temperature of the heat emitter circuit "should be designed to optimise efficiency of the heat pump."
There is also a 55°C ceiling, and it is easy to misread. It applies where a wet heating system is newly installed, or fully replaced, including the heating appliance, emitters and associated pipework. In that case every part should be sized to heat the home at a maximum flow temperature of 55°C. Where that is not feasible in an existing home, for example where there is not enough space for larger radiators, the guidance asks for the lowest design temperature that still meets the heating needs.
MCS, the scheme that certifies heat pump installers, takes the same line in its design standard, MIS 3005-D (Issue 3.0, mandatory for MCS contractors since 5 December 2025). It says high temperature heat pumps should be avoided unless the job needs a flow temperature above 55°C.
How does room-by-room heat loss decide each radiator's size?
Each radiator is sized to replace the heat its own room loses through walls, windows, floor, roof and air leaks on a cold day. The whole-house figure picks the heat pump; the room figures pick the radiators.
MIS 3005-D says the heat load calculation should use indoor temperatures no lower than the ones below, taken from the CIBSE Guide, and should in other respects follow BS EN 12831-1:2017.
- Living room, dining room, bedsitting room: 21°C
- Bedroom, hall and landing, kitchen, toilet: 18°C
- Bathroom: 22°C
The outside temperature comes from a table of UK locations. For Manchester it is minus 2.7°C, or minus 4.5°C on the stricter column. Glasgow is minus 3.5°C, or minus 5.9°C.
Example, using only those standard figures: a Manchester living room designed to stay at 21°C while it is minus 2.7°C outside has to hold a 23.7°C difference. Every wall, window and floor in that room is worked out against that gap, and the total becomes the heat in watts that the radiator, or radiators, must give out.
That is why two rooms with identical radiators can get different answers. A back bedroom with one outside wall may pass, while a bay-fronted living room with a single glazed bay may not.
From 24 March 2027, the 2026 edition of Approved Document L in England adds a note that a room-by-room heat loss calculation should be used when a new heating system, including the heating appliance and/or emitters, is installed, and that sizing a replacement from the output of the old appliance "is not appropriate."
What should your installer put in writing about your radiators?
Before work starts, MIS 3005-D says the customer must be given a written list that includes the heat loss of every room and the type and size of each radiator. Ask for it if you have not been given it, because it is the document that settles every radiator decision.
The list in clause 5.9.2 covers:
- The specific heat loss of every room, in watts per square metre.
- The type and dimensions of the emitters to be used.
- The design emitter temperature, based on the worst performing room.
- The design flow temperature of the water leaving the heat pump.
- The system's seasonal efficiency figure at that flow temperature.
Point 3 is the one to read closely. The weakest room sets the water temperature for the whole house. If one undersized radiator forces the design up from, say, 45°C to 55°C, every other room runs hotter water too, and the efficiency figure in point 5 drops with it. That is the reason to fix a weak radiator rather than design the whole system around it.
Want a radiator-by-radiator answer for your home?
Are microbore pipes a problem for a heat pump?
They can be, so the heat pump design should check the pipe runs rather than assume they are fine. Microbore is narrow-bore pipe, and the question is whether each run can deliver the heat its radiator needs at the cooler design temperature.
Approved Document L treats pipes and radiators as one job, since its 55°C rule for a fully replaced system covers "all parts of the system including pipework and emitters". Upsizing a radiator on a run that cannot feed it does not fix the room.
The answer is usually run by run, not all or nothing. A run to a small room with low heat loss may be fine, while the run to the room that needs the most heat is the one to look at first. Ask for the pipework findings to be written next to the radiator list, so you can see which runs change and why.
Underfloor heating or radiators with a heat pump: which suits your home?
Radiators work with the pipework already in the house; heat pump underfloor heating makes most sense where floors are being lifted anyway, such as an extension or a full renovation.
The cost and disruption of underfloor heating sit in the floor itself. If a floor is being renovated to fit it, for example by replacing a screed or floor deck, Approved Document L gives a target U-value of 0.25 W/m²K for insulating the new floor, and says added insulation is likely to be cost effective where the existing floor is worse than 0.70 W/m²K.
Some homes have both, for example underfloor heating in a new kitchen extension and radiators upstairs. That can work, with one design flow temperature settled for the whole system at design stage.
Which radiator upgrades are usually on the table?
Where a radiator falls short, the fix is a larger emitter, a different type of emitter or less heat loss in the room. The common options:
- A larger radiator. Where the wall allows. MIS 3005-D notes that listed buildings or other design limitations may prevent the use of larger heat emitters.
- A fan-assisted radiator. MIS 3005-D lists the fan convector as its own heat emitter type, separate from a natural convector such as a standard radiator, and its output is checked against the room's heat loss like any other.
- Cutting the room's heat loss instead. Insulation lowers the watts a room needs, so an existing radiator may pass. Our pages on the loft insulation grant and cavity wall insulation grants cover the funding.
Why not just turn the flow temperature up instead?
You can, but every degree higher costs efficiency for the whole house, which is why the design standard asks installers to show you the trade-off. Under clause 5.5.5 of MIS 3005-D, where a design proposes a flow temperature above 55°C, an alternative design at 55°C or lower should also be provided, and the differences in efficiency and energy use must be explained so you can choose.
The same standard lists "Changing the design HP flow temperatures" among the user habits that affect how much energy a system uses. Turning the flow temperature up to make a weak radiator feel warmer treats the symptom in one room and raises the running cost in all of them.
The flow temperature should be settled at design stage and tested at commissioning. If a room is cold after a heat pump goes in, start with the written radiator list and the room heat loss figures. For the wider running cost picture, see are heat pumps worth it.
Does the Boiler Upgrade Scheme grant pay for new radiators?
The grant is a fixed amount off the whole installation, not a separate radiator payment. GOV.UK sets the grant for an air source heat pump at £7,500, with a higher rate for some oil and LPG homes until March 2027. Ofgem's Boiler Upgrade Scheme: Guidance for Property Owners (version 5.2) says the grant is applied upfront as a discount and paid straight to the installer.
The guidance does not set out a radiator allowance, but three of its points bear on radiators.
- Your installer should explain how the installation would affect your home, including heat emitters, and "whether any upgrades may be needed (e.g., radiators)".
- Your installer should visit to carry out a heat loss assessment and give you a quote and a bill impact assessment.
- The quote must be itemised, showing the total cost before any discount, the grant, and what you pay after it.
So any work on your air source heat pump radiators shows up as lines on the same quote that the grant comes off. Read those lines against the written radiator list. Our page on the Boiler Upgrade Scheme explains who qualifies, and our air source heat pump cost guide shows what drives the final figure.
Two limits on GOV.UK matter here. The scheme is limited to England and Wales, so a home in Scotland cannot use it. And a hybrid system pairing a gas boiler with a heat pump cannot get the grant; our hybrid heat pump guide covers that route.
Where does FreeBoilerUpgrade.uk come in?
Our heat pump work covers homes in England and Scotland, with Boiler Upgrade Scheme help where the home is in England. Any radiator changes are agreed in writing with the rest of the heat pump quote before work starts. The hot water side is a separate decision, covered in our heat pump cylinder guide, and what happens on fitting day is set out in our guide to air source heat pump installation.
FAQs
Do I need special radiators for a heat pump?
No. A heat pump connects to the same kind of wet radiator a boiler uses, and products sold as radiators for heat pumps are one choice among many, not a requirement.
How much bigger do heat pump radiators need to be?
There is no fixed multiplier, and the rules of thumb found online differ widely. It depends on the room's heat loss and the flow temperature the system is designed for, and some rooms need no change at all. The real answer for each room is the emitter size on your installer's design.
What are the best radiators to use with a heat pump?
The best one for a room is whichever meets that room's calculated heat loss at your design flow temperature and fits the wall. When comparing radiators, ask for each one's output at that flow temperature, since that is the figure the room calculation is checked against.
Is it cheaper to run underfloor heating or radiators?
There is no single answer, because running cost follows the design flow temperature, not the emitter on its own. If you are weighing the two, ask for a seasonal efficiency figure for each layout, each worked out at its own design flow temperature, and compare those.
Check If You Qualify
Four quick steps. Tap your answers and we'll do the rest.
Sources
- GOV.UK: Approved Document L, Volume 1: Dwellings (2021 edition incorporating 2023 amendments)
- GOV.UK: Approved Document L, Volume 1: Dwellings (2026 edition, takes effect 24 March 2027)
- MCS: MIS 3005-D The Heat Pump Design Standard
- Issue 3.0
- Ofgem: Boiler Upgrade Scheme: Guidance for Property Owners
- version 5.2
- GOV.UK: Apply for the Boiler Upgrade Scheme, what you can get (all checked 12 November 2026)
About This Page
FreeBoilerUpgrade.uk is an installer run by Reliant Energy Solutions Ltd (No. 16100301), incorporated on 25 November 2024. Every boiler is fitted by a Gas Safe registered engineer. We are not part of the government or Ofgem.
- Company: Reliant Energy Solutions Ltd, company number 16100301, address 16 Suite, Turner Business Centre, Middleton, Manchester M24 1RU
- Phone: 07599 995537
- Email: info@freeboilerupgrade.uk
Ready to see which of your radiators would stay?
Ready to Start Saving?
See if your household qualifies for funded ECO4 heating upgrades through the ECO4 scheme.
- 100%
- Free Service
- 60s
- Application
- ECO4
- Eligibility check