Heat Pump Cylinder: Does Your Home Need One, and Where Will It Go?
Last updated:
- The heat pump must meet hot water demand, alone or with supplementary appliances
- A combi boiler cannot stay on as backup under the Boiler Upgrade Scheme
- Ask for the cylinder size and recovery rate in writing
- An oversized cylinder loses standing heat whether you use the water or not
- Unvented cylinders are notifiable building work with two independent safety devices
- Water stored below 60°C should get a weekly pasteurisation cycle, run overnight
- Heat pump cylinders need a larger coil than boiler cylinders
Moving off a combi and not sure where a cylinder could go?
Check If You Qualify- Gas Safe registered engineers
- Company No. 16100301

£7,500
Air source heat pump grant
GOV.UK
£1,500
Extra for oil and LPG homes
GOV.UK, until March 2027
60°C
Weekly legionella cycle target
DECC study, HSE
600mm
Max tundish pipe run
Approved Document G
Why does a heat pump need a cylinder when a combi boiler never did?
Because a heat pump makes heat slowly and at a low temperature, so hot water has to be made ahead of time and stored. A combi fires up hard the moment you open a tap. A heat pump works best gently, and a 2013 study for the then Department of Energy and Climate Change (DECC) described typical heat pump conditions as water at about 45°C, against the 80°C used to test boiler cylinder coils.
The grant rules make storage close to unavoidable. Under regulation 9 of the Boiler Upgrade Scheme Regulations 2022, a heat pump only qualifies if it is capable of meeting the full space heating and hot water heating demands of the property, "whether alone or in combination with supplementary appliances that are not biomass boilers". The same regulations define a supplementary appliance as one that is not fuelled by fossil fuel, so a gas boiler cannot fill that role.
Can you keep your combi boiler for hot water?
Not if you want the grant. Regulation 9(2)(c) says the heat pump must replace the heat generating components of the original heating system, other than any supplementary appliance. GOV.UK's Boiler Upgrade Scheme guidance also says you cannot get a grant for a hybrid heat pump system, giving a gas boiler combined with an air source heat pump as the example.
So in a grant-funded job the combi comes out and its hot water role moves to the cylinder. A heat pump and boiler pair is a hybrid system, which is a different route, as our guide to the hybrid heat pump explains. For how the rest of daily life changes after the switch, see our air source heat pump guide.
Can you keep your old cylinder?
Sometimes. The MCS design standard, MIS 3005-D (Issue 3.0), allows an existing cylinder to be reused, but the insulation on the cylinder and its connected pipes must be brought up to the level required for new installations, and the cylinder size must comply with the heat pump manufacturer's requirements. Where a cylinder is fitted with a heat pump, the heat pump must also be capable of a flow temperature of at least 55°C at design conditions.
What makes a heat pump cylinder different from the one you already have?
The coil. The coil is the pipe inside the cylinder that carries water from the heat pump and passes its heat to the water you use. A heat pump sends that coil cooler water than a boiler does, so the coil needs far more surface to move the same heat.
The DECC study measured the difference. The quick recovery coils it tested had surface areas of 2 and 3 m², compared with 0.6 to 1 m² in standard tanks. The same study found that fast recovery coils shorten reheat times, so a heat pump paired with a small boiler coil leaves you waiting longer for the tank to recover.
An existing cylinder from a system boiler is therefore worth checking rather than assuming, starting with the size of its coil.
The coil rating on the label can mislead
A coil's kW rating is usually measured with 80°C water, which a heat pump will not supply. The DECC study noted that ratings are stated under the BS EN 12897 test, heated by 80°C water, and recommended that manufacturers give ratings under conditions suitable for a heat pump. When you compare cylinders, ask for the figure at heat pump temperatures, not the headline one.
What size heat pump cylinder does your household need?
The right heat pump cylinder size is the smallest one that still covers your busiest day of hot water use. The MCS design standard, MIS 3005-D (Issue 3.0), calculates the average daily hot water demand as 45 multiplied by N, where N is the number of bedrooms plus one or the number of known occupants, whichever is greater. An appropriately sized cylinder is then specified, and your installer must give you the cylinder specification and its recovery rate in writing before installation starts. Your own pattern of showers, baths and washing up still matters, and the questions below show why.
Two findings from the DECC tests shape the decision:
- Stored water is cooler, so you need more of it. The study found that cylinder volume needs to be larger at lower storage temperatures to give enough large draw-offs one after another, such as two showers back to back.
- Too big wastes heat. A cylinder loses the same standing heat every day whether you use the water or not. The study advised installers to avoid large cylinders unless the household asks for extra storage or heats water on off-peak electricity and uses a lot.
The questions that decide your heat pump cylinder size:
- How many people shower or bathe, and at what times of day?
- Does anyone take long baths, or are there several showers in a row each morning?
- Will the cylinder be heated on an off-peak tariff, once or twice a day?
- What temperature will the water be stored at?
Where can an air source heat pump cylinder go if you have no airing cupboard?
Anywhere inside the warm part of the home that can take its size, its weight and a safe discharge pipe. The DECC study was blunt that no cylinders should be installed outside the heated space, because heat lost from a tank in a cold space is simply wasted.
Three things limit the spot more than people expect:
- Weight. Example: a 200 litre cylinder holds about 200 kg of water, before the weight of the tank itself, so the floor has to carry it.
- The discharge route. For an unvented cylinder, Approved Document G says the tundish (the open funnel that shows when a safety valve has released water) must be in the same space as the cylinder, with no more than 600mm of pipe from the valve, and the discharge must run to a safe place open to the air.
- Pipe runs. The study said the pipework between the heat pump and the cylinder must be well insulated along its whole length, so a long run to a far corner of the house adds loss as well as cost.
A utility room or a large cupboard inside the insulated part of the house can meet all three. Where height is the problem, ask whether a horizontal heat pump cylinder would suit the space. The air source heat pump installation page shows where this choice sits in the wider survey.
Vented or unvented: which heat pump hot water cylinder will you get?
If your home has no cold water storage cistern, a vented cylinder has nothing to feed it, so an unvented cylinder fed from the mains is the type that fits. The two types are defined in Approved Document G, the Building Regulations guidance for hot water safety in England.
- Vented: fed from a cold water storage cistern, with a vent pipe running from the top of the cylinder back over that cistern.
- Unvented: fed straight from the mains supply pipe or a dedicated cistern without a vent pipe. Expansion is handled inside or outside the cylinder.
What makes an unvented cylinder safe and legal?
An unvented cylinder holds hot water under pressure, so the rules are strict. Approved Document G says:
- It needs at least two independent safety devices on top of the thermostat, to guard against excess pressure, and the system must stop stored water ever exceeding 100°C.
- A system up to 500 litres and under 45kW should be a proprietary unit or package, marked with its maximum primary circuit pressure and flow temperature.
- Installing one is notifiable building work, which must be notified to building control before work starts.
- If the installer is registered with a competent person scheme for unvented systems, they self-certify instead, and you should receive a building regulations certificate of compliance within 30 days of the work finishing.
Keep that certificate. It is your proof that the unvented work was signed off under the Building Regulations. Approved Document G also says the hot water supply to a bath should be limited to a maximum of 48°C with a blending valve, which matters if your cylinder is set hotter than that.
These are the rules for England. In Scotland, the Scottish Government sets its own building standards regulations and technical guidance.
How hot should the cylinder be, and what is a legionella cycle?
HSE guidance says hot water should be stored at 60°C or more and reach 50°C at the tap within one minute, because legionella bacteria can grow when water sits between 20 and 45°C. Those figures come from HSE's technical guidance HSG274 Part 2 (2024), which is written for employers and others in control of premises. HSE says following it is not compulsory, but it is the clearest official guide to safe storage temperatures.
A heat pump runs most efficiently when it heats water to a lower temperature, so many systems store water below 60°C day to day. The DECC study found that these systems are generally set to raise the water to 60°C for one to three hours once a week, usually using the cylinder's immersion heater. This weekly boost is the heat pump legionella cycle.
The study also found that the bottom of the cylinder did not always reach the right temperature during the cycle. Its advice for installers:
- Run it overnight, when nobody is drawing hot water.
- Fit the immersion low in the cylinder where possible.
- Use a long enough immersion for at least 95% of the water to reach the target temperature.
Ask at handover what day and time your cycle runs, and whether the heat pump or the immersion does the work. A cycle set for 7am on a Monday heats water just as the household is using it.
Day to day, the cylinder thermostat matters as much as the weekly boost. The DECC study warned that the cylinder set point must be lower than the heat pump's delivery temperature. Set it higher and the heat pump keeps trying to heat beyond its ability, may trip out on high temperature and uses a lot of electricity.
Will a grant pay for the cylinder?
GOV.UK sets the Boiler Upgrade Scheme grant by type of heat pump, at £7,500 for an air source model, with no separate amount for a cylinder. Until March 2027, an extra £1,500 is available where the home is heated by oil or LPG and has no mains gas connection. The installer deducts it from the price upfront, so you pay the balance. Whether the cylinder pushes your final bill above the grant depends on the full quote. This page does not give a cylinder price, because it depends on the size and type chosen at the survey. Our Boiler Upgrade Scheme page covers who qualifies, and typical totals are on the air source heat pump cost page.
Status, checked 12 November 2026: GOV.UK lists £7,500 for an air source heat pump in England and Wales; homes in Scotland are outside the Boiler Upgrade Scheme.
For lower-income homes in England, the DESNZ Warm Homes: Local Grant policy guidance (July 2026) lists "Hot Water Cylinder/Tank", hot water cylinder insulation and a hot water cylinder thermostat among its example measures. It also says that where a home is owner occupied the upgrade should be fully funded. Greater Manchester is outside the national scheme; see our page on heat pumps in Manchester for the detail. How the national scheme works is on our Warm Homes: Local Grant page.
What about a heat battery instead of a cylinder?
A heat battery cannot be funded through the Warm Homes: Local Grant yet. The same guidance says heat batteries will not be eligible until they can be MCS certified, and that phase change heat batteries for hot water are not yet a recognised technology in SAP, the method behind EPC ratings. MCS consulted on a standard for thermal energy storage in March 2025 and announced a pilot in September 2025, so this may change. For now, the guidance lists the hot water cylinder, not a heat battery, among its measures.
Planning a heat pump and wondering about the hot water side?
FAQs
Are heat pump hot water cylinders worth it?
Yes for most homes moving off a combi boiler, because a heat pump heats water slowly and needs it stored ahead of time. If you already have a cylinder, it depends on its coil. In the DECC tests, the coils in the heat pump cylinders were so large (the lowest rated at 23kW) that the reheat time was set by the heat pump, not the cylinder. The same report found that low heat pump flow temperatures and low cylinder storage temperatures give the best system efficiency.
Can a heat pump cylinder go in a loft?
It is possible, but a loft makes the job harder. For an unvented cylinder the tundish has to sit in the loft beside it, and the discharge pipe then needs a safe route from roof level down to the open air. The insulated pipes from the outdoor unit also run further, and in an unheated loft they pass through a cold space. A converted loft room inside the warm part of the home is a better case than an open, unheated loft.
Do you run out of hot water with a heat pump?
You can if the cylinder is too small for your heaviest day. In the DECC tests, a 180 litre cylinder ran dry partway through the largest daily draw-off pattern, delivering 6.94kWh of the 11.67kWh that pattern needed. Sizing for your busiest morning, not an average day, is what prevents it.
What size hot water tank do I need?
Think in baths as well as people. The DECC report worked out, assuming a perfectly stratified tank, that two baths in a row need 150 litres of hot water stored at 50°C, and more than that at 45°C. It suggested some families of more than two adults may need a 180 litre cylinder, and called 150 to 160 litres a reasonable compromise. It saw solar thermal panels as one of the main reasons to go above 180 litres.
Check If You Qualify
Four quick steps. Tap your answers and we'll do the rest.
Sources
- legislation.gov.uk: The Boiler Upgrade Scheme (England and Wales) Regulations 2022, regulation 9
- GOV.UK: Boiler Upgrade Scheme guidance (what you can get)
- GOV.UK: Approved Document G, Sanitation, hot water safety and water efficiency
- GOV.UK: Investigation of the interaction between hot water cylinders, buffer tanks and heat pumps (DECC, 2013)
- HSE: Legionnaires' disease
- HSG274 Part 2
- hot and cold water systems (2024)
- Scottish Government: Building standards
- DESNZ: Warm Homes: Local Grant policy guidance, July 2026 (all checked 12 November 2026)
About This Page
FreeBoilerUpgrade.uk is an installer run by Reliant Energy Solutions Ltd (No. 16100301), incorporated on 25 November 2024. Every boiler is fitted by a Gas Safe registered engineer. We are not part of the government or Ofgem.
- Company: Reliant Energy Solutions Ltd, company number 16100301, address 16 Suite, Turner Business Centre, Middleton, Manchester M24 1RU
- Phone: 07599 995537
- Email: info@freeboilerupgrade.uk
Want to talk through your hot water setup?
Ready to Start Saving?
See if your household qualifies for funded ECO4 heating upgrades through the ECO4 scheme.
- 100%
- Free Service
- 60s
- Application
- ECO4
- Eligibility check